Related Experiment Videos
Role of ultrasound in urinary incontinence evaluation
A Bergman1, M Vermesh, C A Ballard
1Women's Hospital, USC School of Medicine.
Urology
|May 1, 1989
Abstract:
Transrectal ultrasound was used to assess anatomic support of the urethrovesical junction (UVJ) in continent and stress incontinent women. UVJ drop on straining of less than 1 cm as assessed by transrectal ultrasound correlated well with good support to the UVJ. Drop of UVJ of more than 1 cm on straining correlated with poor support to bladder neck and stress urinary incontinence. The transrectal technique is quick and easy to perform and interpret.