Single Chemosensor for Double Analytes: Spectrophotometric Sensing of Cu(2+) and Fluorogenic Sensing of Al(3+) Under
Jie Yang1, Ze-li Yuan2, Guang-qing Yu1
1School of Pharmacy, Zunyi Medical University, Zunyi, Guizhou, 563003, China.
Journal of Fluorescence
|November 5, 2015
Abstract:
(E)-N-((8-Hydroxy-1,2,3,5,6,7-hexahydropyrido-[3,2,1-ij]-quinolin-9-yl)methylene)-4-tert-butyl -benzhydrazide has been developed as a single, dual-functional chemosensor. The chemosensor showed a good selectivity and sensitivity toward to Al(3+) and Cu(2+) at a low detection limit, respectively. Theoretical calculations have also been carried out to understand the configuration of the complexes.
Related Concept Videos
Photoluminescence: Applications
1.2K
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
1.2K
Fluorescence and Phosphorescence: Instrumentation
1.9K
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
1.9K
Atomic Fluorescence Spectroscopy
1.1K
Atomic fluorescence spectroscopy (AFS) is an analytical technique that involves the electronic transitions of atoms in a flame, furnace, or plasma being excited by electromagnetic (EM) radiation. When these atoms absorb energy, they become excited and subsequently release energy as they return to their original state. This emitted light, or "fluorescence," is observed at a right angle to the incident beam. Both absorption and emission processes transpire at distinct wavelengths, which...
1.1K
UV–Vis Spectrometers
4.5K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
4.5K