[A simple preparation method of an electric heating apparatus for heating capillary chromatographic columns and its application in liquid chromatography-mass spectrometry system]
Related Experiment Video
Updated: Mar 30, 2026

Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Abstract:
For deep coverage of proteome, especially in performing qualitative identification and quantitative analysis of low-abundance proteins, the most commonly used method is the application of a longer capillary chromatographic column or a capillary column packed with smaller particle sizes. However, this causes another problem, the very high back pressure which results in liquid leaks in some connection parts in a liquid chromatograph. To solve this problem, an electric heating apparatus was developed to raise the temperature of a capillary column for reducing its back pressure, which was further applied in a capillary high performance liquid chromatography-tandem mass spectrometry system (cHPLC-MS/MS), and evaluated in the terms of chromatographic column back pressure and chromatographic column efficiency using bovine serum albumin (BSA) tryptic digests and yeast tryptic digests, separately. The results showed that at the optimum current, our electric heating apparatus could reduce the column pressure of a capillary column packed with 3 µm packing materials by at least 50% during the separation of BSA tryptic digestion and yeast tryptic digestion, compared with that without electric heating. The column efficiency was also increased slightly. This suggested that the electric heating apparatus can significantly reduce the column pressure, which provides an efficient way to use capillary chromatographic columns packed with smaller sizes of particles at a lower pressure.
More Related Videos
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Capillary Electrophoresis: Instrumentation
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....