Prosthetic management of malpositioned implant using custom cast abutment
Aishwarya Chatterjee1, Mallikarjuna Ragher2, Sanket Patil3
1Department of Dentistry, SMS Medical College and Hospital, Jaipur, Rajasthan, India.
Abstract:
Two cases are reported with malpositioned implants. Both the implants were placed 6-7 months back. They had osseointegrated well with the surrounding bone. However, they presented severe facial inclination. Case I was restored with custom cast abutment with an auto polymerizing acrylic gingival veneer. Case II was restored with custom cast UCLA type plastic implant abutment. Ceramic was directly fired on the custom cast abutments. The dual treatment strategy resulted in functional and esthetic restorations despite facial malposition of the implants.