Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Computed Tomography01:10

Computed Tomography

9.5K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
9.5K
Radiological Investigation I: X-ray and CT01:30

Radiological Investigation I: X-ray and CT

1.6K
Radiological investigations, including X-rays and computed tomography (CT) scans, are critical for diagnosing and evaluating various medical conditions. These imaging techniques provide valuable insights into the body's internal structures, aiding in the detection of abnormalities, assessment of disease progression, and development of treatment strategies. This article delves into two primary radiological investigations, chest X-rays and CT scans, outlining their purpose, procedures, and...
1.6K
Imaging Studies for Cardiovascular System V: CT01:28

Imaging Studies for Cardiovascular System V: CT

559
Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
559
X-ray Imaging01:24

X-ray Imaging

11.0K
German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with...
11.0K
Imaging Studies I: CT and MRI01:14

Imaging Studies I: CT and MRI

1.2K
Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
1.2K
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

660
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
660

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Discovery of Serum Exosomal Protein Biomarkers for Early- and Late-Stage Lung Cancer Through Comparative Proteomic Analysis.

Anti-cancer agents in medicinal chemistry·2026
Same author

SMUPhantom: a 3D-printable modular CT perfusion phantom for quantitative evaluation of tissue-mimicking dynamic contrast behavior.

Biomedical physics & engineering express·2026
Same author

[Determination of perfluorinated compounds, antibiotics and pesticides in drinking water by automated solid phase extraction with ultra-performance liquid chromatography-tandem mass spectrometry].

Se pu = Chinese journal of chromatography·2026
Same author

Giant Panda Feces-Derived <i>Weissella confusa</i> BSP201703 Protects Mice Against Chronic ETEC Infection by Repairing Intestinal Barrier Function.

Veterinary sciences·2026
Same author

Poorly differentiated thyroid carcinoma: a case report and literature review.

Frontiers in oncology·2026
Same author

Error Detection in Emergency Radiology Reports Using a Large Language Model: Multistage Evaluation Study.

Journal of medical Internet research·2026

Related Experiment Video

Updated: Mar 30, 2026

Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
08:41

Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease

Published on: March 24, 2023

1.9K

A Simple Low-dose X-ray CT Simulation from High-dose Scan.

Dong Zeng1, Jing Huang1, Zhaoying Bian1

  • 1School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China.

IEEE Transactions on Nuclear Science
|November 7, 2015
PubMed
Summary

This study introduces a novel sinogram domain method for simulating low-dose X-ray computed tomography (CT) from high-dose scans. The technique accurately generates low-dose CT data, optimizing patient radiation exposure.

Keywords:
X-ray CThigh-doselow-dosesimulation

More Related Videos

High Resolution 3D Imaging of Ex-Vivo Biological Samples by Micro CT
08:57

High Resolution 3D Imaging of Ex-Vivo Biological Samples by Micro CT

Published on: June 21, 2011

19.3K
X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
08:30

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging

Published on: September 11, 2011

15.0K

Related Experiment Videos

Last Updated: Mar 30, 2026

Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
08:41

Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease

Published on: March 24, 2023

1.9K
High Resolution 3D Imaging of Ex-Vivo Biological Samples by Micro CT
08:57

High Resolution 3D Imaging of Ex-Vivo Biological Samples by Micro CT

Published on: June 21, 2011

19.3K
X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
08:30

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging

Published on: September 11, 2011

15.0K

Area of Science:

  • Medical Imaging
  • Radiological Physics

Background:

  • Optimizing radiation dose in medical imaging is crucial for patient safety.
  • Low-dose X-ray computed tomography (CT) simulation from high-dose scans is essential for dose reduction strategies.

Purpose of the Study:

  • To develop a simple and accurate low-dose CT simulation strategy in the sinogram domain.
  • To enable accurate generation of low-dose CT data from existing high-dose scans.

Main Methods:

  • A relationship between low- and high-dose scan incident fluxes was determined using repeated projection measurements.
  • Low-dose CT transmission data was simulated by scaling high-dose data and adding Poisson and Gaussian noise.
  • Filtered back-projection (FBP) algorithm was used for image reconstruction.

Main Results:

  • The proposed strategy accurately simulates low-dose CT sinogram data from high-dose scans.
  • Qualitative and quantitative measurements confirmed the accuracy of the simulated low-dose CT data.
  • Verification against existing simulation tools showed comparable or superior results.

Conclusions:

  • The developed sinogram domain strategy provides an effective method for simulating low-dose CT data.
  • This approach aids in optimizing radiation doses for patients undergoing CT scans.
  • The method is validated through simulations and real-world scan data.