Related Experiment Video
Updated: Mar 30, 2026

Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
Comparison of SpO2 values from different fingers of the hands
Gokcen Basaranoglu1, Mefkur Bakan1, Tarik Umutoglu1
1Department of Anesthesiology and Reanimation, Bezmialem Vakif University Faculty of Medicine, Istanbul, Turkey.
Abstract:
Pulse oximetry is a frequently used tool in anesthesia practice. Gives valuable information about arterial oxygen content, tissue perfusion and heart beat rate. In this study we aimed to provide the comparison of peripheral capillary hemoglobin oxygen saturation (SpO2) values among every finger of the two hands. Thirty-seven healthy volunteers from operative room stuffs between the ages of 18-30 years were enrolled in the study. They were monitored after 5 min of rest. After their non invasive blood pressure, heart rate, fasting time and body temperature were measured, SpO2 values were obtained from every finger and each of two hands fingers with the same pulse oximetry. All the SpO2 values were obtained after at least 1 min of measurement period. A total of 370 SpO2 measurements from 37 volunteers were obtained. The highest average SpO2 value was measured from right middle finger (98.2 % ± 1.2) and it was statistically significant when compared with right little finger and left middle finger. The second highest average SpO2 value was measured from right thumb and it was statistically significant only when compared with left middle finger (the finger with the lowest average SpO2 value) (p < 0.05). SpO2 measurement from the fingers of the both hands with the pulse oximetry, the right middle finger and right thumb have statistically significant higher value when compared with left middle finger in right-hand dominant volunteers. We assume that right middle finger and right thumb have the most accurate value that reflects the arterial oxygen saturation.
More Related Videos
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Special considerations while measuring pulse