Related Experiment Video
Updated: Mar 30, 2026

Cooling or Warming the Esophagus to Reduce Esophageal Injury During Left Atrial Ablation in the Treatment of Atrial Fibrillation
Published on: March 15, 2020
Myocardial injury during radiofrequency and cryoablation of typical atrial flutter
Serkan Saygi1,2, Nikola Drca3, Per Insulander3
1All Department of Cardiology, Karolinska Institute, Karolinska University Hospital, Stockholm, Sweden. serkankard@gmail.com.
Purpose:
Cardiac enzyme elevation after radiofrequency (RF) catheter ablation of atrial flutter (AFL) is common. Some studies found that cryoablation (CRYO) of AFL, compared to RF, is associated with higher levels of troponin, a finding that may indicate CRYO causes a greater amount of myocardial injury than RF. However, other investigations found no significant differences between troponin levels after CRYO versus RF. We have in a randomized study compared the post-procedural troponin I levels in RF and CRYO and the possible relation to procedural outcome and complications.
Methods:
We randomized 153 patients with cavotricuspid isthmus (CTI)-dependent AFL to CRYO or RF (78 CRYO; 75 RF). RF was performed with a 3.5-mm open-irrigated-tip catheter, and CRYO was performed with an 8-mm-tip catheter. Troponin I levels were measured before and 6 h after ablation.
Results:
Acute procedural success was achieved in 71/75 patients in the RF and in 72/78 patients in the CRYO. Troponin I levels were significantly elevated in both groups (baseline 0.012, 6th hour 0.35 ng/ml; p < 0.001). Troponin I levels were similar for RF and CRYO. Troponin I levels were higher in patients with acute failure compared to patients with acute success (0.48 ± 0.4 and 0.34 ± 0.16 ng/ml, p = 0.029); however, there was no difference between patients with or without late recurrence. There were no major complications in any group.
Conclusion:
RF and CRYO for CTI-dependent AFL resulted in similar amounts of procedural myocardial injury. Troponin I levels had no prognostic value for late recurrence of AFL and there were no complications related to high troponin I levels.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology