[Causal analysis and impact of a systematic error detected about consumption associated with trastuzumab]
Nuria Bujaldón Querejeta1, Dolores Camacho Romera1, José Antonio Pomares Pastor1
1Servicio de Farmacia Hospital Universitario Sant Joan, Alicante. España.. bujaldonquerejetanuria@gmail.com.
Objective:
determine the cause of the constant difference between the theoretical and real number of trastuzumab units consumed in an Intravenous Mixtures Unit.
Methods:
was studied the manual and electronic full procedure about preparing mixtures with trastuzumab. Was performed by visual observation and review of quantitative monitoring data from the electronic preparation support and safe system of the application Farmis-Oncofarm®.
Results:
difference between the optimum volume of trastuzumab contained in the summary of product characteristics and the same included in Farmis_Oncofarm® was found. Also found a defect of the optimum volume of 10ml syringes used in the reconstitution vials process.
Conclusions:
the default in the optimal volume of 10ml syringes used in the reconstitution process increases the real consumed units of trastuzumab. This produces a significant economic impact calculated in an annual additional cost in approximately 46.508 € without negative consequences for the patient.
More Related Videos
Related Concept Videos
Therapeutic Drug Monitoring: Affecting Factors
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Cancer Survival Analysis
Pharmacovigilance
This process, termed pharmacovigilance, aims to detect, evaluate, and minimize harmful effects related to medication use. The data collection for pharmacovigilance depends on spontaneous reporting systems, where healthcare professionals or patients voluntarily report suspected ADRs.
In some cases, there...
Therapeutic Drug Monitoring: Drug Analysis Methods
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...