Related Experiment Video
Updated: Mar 30, 2026

Hydra, a Computer-Based Platform for Aiding Clinicians in Cardiovascular Analysis and Diagnosis
Published on: September 26, 2018
Methods of defining hypertension in electronic medical records: validation against national survey data
Mingkai Peng1, Guanmin Chen2, Gilaad G Kaplan3
1Department of Community Health Sciences, University of Calgary, Calgary, AB, Canada T2N 4Z6.
Background:
Electronic medical records (EMR) can be a cost-effective source for hypertension surveillance. However, diagnosis of hypertension in EMR is commonly under-coded and warrants the needs to review blood pressure and antihypertensive drugs for hypertension case identification.
Methods:
We included all the patients actively registered in The Health Improvement Network (THIN) database, UK, on 31 December 2011. Three case definitions using diagnosis code, antihypertensive drug prescriptions and abnormal blood pressure, respectively, were used to identify hypertension patients. We compared the prevalence and treatment rate of hypertension in THIN with results from Health Survey for England (HSE) in 2011.
Results:
Compared with prevalence reported by HSE (29.7%), the use of diagnosis code alone (14.0%) underestimated hypertension prevalence. The use of any of the definitions (38.4%) or combination of antihypertensive drug prescriptions and abnormal blood pressure (38.4%) had higher prevalence than HSE. The use of diagnosis code or two abnormal blood pressure records with a 2-year period (31.1%) had similar prevalence and treatment rate of hypertension with HSE.
Conclusions:
Different definitions should be used for different study purposes. The definition of 'diagnosis code or two abnormal blood pressure records with a 2-year period' could be used for hypertension surveillance in THIN.
Related Concept Videos
Hypertension III: Clinical Manifestations and Diagnostic Studies
Hypertension I: Introduction
Errors occurring during blood pressure monitoring
Several factors...
Methods of Documentation VII: EMR
Hypertension and Regulation of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...

