Related Experiment Video
Updated: Mar 30, 2026

Author Spotlight: Advancing Pediatric Epilepsy Surgery in Children Through Novel Biomarkers and Enhanced Localization
Published on: September 20, 2024
Ictal EEG Source Imaging for Presurgical Evaluation of Refractory Focal Epilepsy
Mohammad Ashfak Habib1, Fatimah Ibrahim2, Mas S Mohktar2
1Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia; Centre for Innovation in Medical Engineering (CIME), Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia; Department of Computer Science & Engineering, Chittagong University of Engineering & Technology, Chittagong, Bangladesh.
Background:
Electroencephalography source imaging (ESI) is a promising tool for localizing the cortical sources of both ictal and interictal epileptic activities. Many studies have shown the clinical usefulness of interictal ESI, but very few have investigated the utility of ictal ESI. The aim of this article is to examine the clinical usefulness of ictal ESI for epileptic focus localization in patients with refractory focal epilepsy, especially extratemporal lobe epilepsy.
Methods:
Both ictal and interictal ESI were performed by the use of patient-specific realistic forward models and 3 different linear distributed inverse models. Lateralization as well as concordance between ESI-estimated focuses and single-photon emission computed tomography (SPECT) focuses were assessed.
Results:
All the ESI focuses (both ictal and interictal) were found lateralized to the same hemisphere as ictal SPECT focuses. Lateralization results also were in agreement with the lesion sides as visualized on magnetic resonance imaging. Ictal ESI results, obtained from the best-performing inverse model, were fully concordant with the same cortical lobe as SPECT focuses, whereas the corresponding concordance rate is 87.50% in case of interictal ESI.
Conclusions:
Our findings show that ictal ESI gives fully lateralized and highly concordant results with ictal SPECT and may provide a cost-effective substitute for ictal SPECT.
More Related Videos
08:20Brain Source Imaging in Preclinical Rat Models of Focal Epilepsy using High-Resolution EEG Recordings
Published on: June 6, 2015
09:00Investigating the Function of Deep Cortical and Subcortical Structures Using Stereotactic Electroencephalography: Lessons from the Anterior Cingulate Cortex
Published on: April 15, 2015