Related Experiment Video
Updated: Mar 30, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Novel Technique: Knee Arthrodesis Using Trabecular Metal Cones with Intramedullary Nailing and Intramedullary
Blake E Peterson1, Sonny Bal1, Ajay Aggarwal1
1Department of Orthopaedic Surgery, University of Missouri, Columbia, Missouri.
Abstract:
The failed total knee arthroplasty is a challenge to the surgeon and the patient. Infection, bone loss, and instability lead to a chronically painful and dysfunctional limb. Two-stage revision arthroplasty has been successful in clearing a majority of periprosthetic joint infections. However, there are many cases when the multiply revised and infected total knee arthroplasty cannot be salvaged. We report, a review of knee arthrodesis and a novel technique to manage significant bone loss. The use of trabecular metal cones and a long intramedullary nail can be used in concert with an autologous intramedullary bone graft to provide a stable, length restoring construct with sufficient biology to heal very large bone voids. With this technique we have successfully restored function and stability in the failed knee arthroplasty.