Related Experiment Video
Updated: Mar 30, 2026

The Use of an Automated System GreenFeed to Monitor Enteric Methane and Carbon Dioxide Emissions from Ruminant Animals
Published on: September 7, 2015
Reliable low-cost devices for monitoring ammonia concentrations and emissions in naturally ventilated dairy barns
Xiang Wang1, Pius M Ndegwa1, HungSoo Joo1
1Biological Systems Engineering, Washington State University, PO Box 646120, Pullman, WA 99164, USA.
Abstract:
This research investigated the use of two relatively cost-effective devices for determining NH3 concentrations in naturally ventilated (NV) dairy barns including an Ogawa passive sampler (Ogawa) and a passive flux sampler (PFS). These samplers were deployed adjacent to sampling ports of a photoacoustic infrared multigas spectroscope (INNOVA), in a NV dairy barn. A 3-day deployment period was deemed suitable for both passive samplers. The correlations between concentrations determined with the passive samplers and the INNOVA were statistically significant (r = 0.93 for Ogawa and 0.88 for PFS). Compared with reference measurements, Ogawa overestimated NH3 concentrations in the barn by ∼ 14%, while PFS underestimated NH3 concentrations by ∼ 41%. Barn NH3 emission factors per animal unit (20.6-21.2 g d(-1) AU(-1)) based on the two passive samplers, after calibration, were similar to those obtained with the reference method and were within the range of values reported in literature.
Related Concept Videos
Bioreactor Controls-I
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...