Related Experiment Video
Updated: Mar 30, 2026

A Rapid and Quantitative Fluorimetric Method for Protein-Targeting Small Molecule Drug Screening
Published on: October 16, 2015
A 'turn-on' fluorescent chemosensor for quantification of serum albumin in aqueous solution at neutral pH
Yuanyuan Li1, Kai Li2, Juan He1
1School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou, 450001, People's Republic of China.
Abstract:
A fluorescent chemosensor 1 (4-diethylamino-2'-hydroxychalcone) for detecting serum albumin with long-wavelength emission, good selectivity and facile synthesis was reported. Upon the addition of bovine serum albumin (BSA) to an aqueous solution of 1 at neutral pH, a 'turn-on' fluorescence response was observed at 596 nm based on a hydrophobic binding mode between 1 and BSA. A linear range of 0.10-1.00 mg/mL and a detection limit of 9.1 µg/mL for BSA were obtained, respectively. Moreover, 1 was successfully applied to detect BSA in real bovine serum samples with satisfied recovery and accuracy, which suggested that 1 could serve as a valid and effective fluorescent chemosensor for quantification of BSA.
Related Concept Videos
Photoluminescence: Applications
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...