Respiratory protection for firefighters--Evaluation of CBRN canisters for use during overhaul II: In mask analyte
Leaton Jones1, Jefferey L Burgess1, Heath Evans2
1a Division of Community, Environment, and Policy, Mel and Enid Zuckerman College of Public Health, University of Arizona , Tucson , Arizona.
Abstract:
According to the National Fire Protection Association there were 487,500 structural fires in the U.S. in 2013. After visible flames are extinguished firefighters begin the overhaul stage where remaining hot spots are identified and further extinguished. During overhaul, a significant amount of potentially hazardous chemicals can remain in the ambient environment. Previous research suggests that the use of air purifying respirators fitted with chemical, biological, radiological, and nuclear (CBRN) canisters may reduce occupational exposure. This study used large scale burns of representative structural materials to perform side-by-side, filtering, and service-life evaluations of commercially available CBRN filters using two head forms fitted with full-face respirators and a dynamic breathing machine. Three types of CBRN canisters and one non-CBRN cartridge were challenged in repetitive post-fire environments. Tests were conducted with two different breathing volumes and rates for two sampling durations (0-15 min and 0-60 min). Fifty-five different chemicals were selected for evaluation and results indicate that 10 of the 55 chemicals were present in the post-fire overhaul ambient environment. Acetaldehyde and formaldehyde were found to be the only two chemicals detected post filter but were effectively filtered to below ACGIH TLVs. Counter to our prior published work using continuous flow filter evaluation, this study indicates that, regardless of brand, CBRN filters were effective at reducing concentrations of post-fire ambient chemicals to below occupational exposure limits. However, caution should be applied when using CBRN filters as the ambient formaldehyde level in the current study was 8.9 times lower than during the previous work.
More Related Videos
Related Concept Videos
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Chemical Factors Affecting Respiration Centers
CO2 has a potent influence on respiration and is strictly regulated....