Non-Sequential Spectral Acquisitions and Data Reconstruction to Remove Time-Dependent Effects from X-Ray Spectra
Phillip Gopon1, Peter Sobol, John Fournelle
1Department of Geoscience, University of Wisconsin 1215 W. Dayton St., Madison, Wisconsin 53706 USA.
Abstract:
X-ray spectroscopy techniques may require prolonged exposure of a sample to an electron beam to generate X-rays. With typical spectroscopic methods the measured signal is acquired while varying the independent parameter in a systematic way, for example, stepping a photon detector in a series of energy steps from one end of the range of interest to the other incrementally or varying the energy of the incoming excitation incrementally. This can be a time-consuming process when signal strength is low, and if the sample is affected by prolonged beam exposure it could potentially change the shape and position of the obtained X-ray spectrum. Hydrocarbon contamination is of particular concern in electron beam instruments because of the interaction between the hydrocarbons and the electron beam at the point of impact on the sample surface. The authors suggest that hydrocarbon contamination does affect the generated spectra and present methods for removing this (and other) time-dependent artifacts for low-voltage X-rays. The software is freely available as a compiled Windows executable and as source code (http://geoscience.wisc.edu/geoscience/?p=16417).
More Related Videos
10:03Proton Transfer and Protein Conformation Dynamics in Photosensitive Proteins by Time-resolved Step-scan Fourier-transform Infrared Spectroscopy
Published on: June 27, 2014
10:18Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
Published on: February 21, 2017
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
Tandem Mass Spectrometry
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
Reconstruction of Signal using Interpolation
NMR Spectrometers: Resolution and Error Correction