Systematic Hearing Performance Evaluation Process for Adolescents with Cochlear Implantation at Early Ages
Published on: March 24, 2023
Comparison of speech intelligibility measures for an electronic amplifying earmuff and an identical passive
David C Byrne1, Catherine V Palmer2
1National Institute for Occupational Safety and Health, Cincinnati, OH;
Abstract:
The purpose of this study was to identify any differences between speech intelligibility measures obtained with MineEars electronic earmuffs (ProEars, Westcliffe, CO, USA) and the Bilsom model 847 (Sperian Hearing Protection, San Diego, CA, USA), which is a conventional passive-attenuation earmuff. These two devices are closely related, since the MineEars device consisted of a Bilsom 847 earmuff with the addition of electronic amplification circuits. Intelligibility scores were obtained by conducting listening tests with 15 normal-hearing human subject volunteers wearing the earmuffs. The primary research objective was to determine whether speech understanding differs between the passive earmuffs and the electronic earmuffs (with the volume control set at three different positions) in a background of 90 dB(A) continuous noise. As expected, results showed that speech intelligibility increased with higher speech-to-noise ratios; however, the electronic earmuff with the volume control set at full-on performed worse than when it was set to off or the lowest on setting. This finding suggests that the maximum volume control setting for these electronic earmuffs may not provide any benefits in terms of increased speech intelligibility in the background noise condition that was tested. Other volume control settings would need to be evaluated for their ability to produce higher speech intelligibility scores. Additionally, since an extensive electro-acoustic evaluation of the electronic earmuff was not performed as a part of this study, the exact cause of the reduced intelligibility scores at full volume remains unknown.
More Related Videos
07:00Electrically Evoked Stapedius Reflex Measurements in Cochlear Implantation and Its Application in the Postoperative Fitting Process
Published on: June 21, 2024
12:43A Protocol for Comprehensive Assessment of Bulbar Dysfunction in Amyotrophic Lateral Sclerosis ALS
Published on: February 21, 2011
Related Concept Videos
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...