Related Experiment Video
Updated: Mar 30, 2026

Systematic Hearing Performance Evaluation Process for Adolescents with Cochlear Implantation at Early Ages
Published on: March 24, 2023
Listening levels of teenage iPod users: does measurement approach matter?
Nicole C Haines1, William E Hodgetts1, Amberley V Ostevik1
1University of Alberta, Canada.
Abstract:
The main objective of this study was to determine the influence of background noise levels and measurement approach on user-selected listening levels (USLLs) chosen by teenaged MP3 player users. It was hypothesized that the presence of background noise would (i) increase the USLL across all measurement approaches, (ii) result in no significant USLL differences between survey reports, objective lab measures or calibrated self-report field measures, and (iii) cause no interaction effect between level of background noise and measurement approach. There were two independent variables in this study: the level of background noise and measurement approach. The first independent variable, level of background noise, had two levels: quiet and transportation noise. The second independent variable, measurement approach, had three levels: survey, objective in-ear lab measurement and calibrated self-report field measurement. The dependent variable was ear canal A-weighted sound pressure level (dBA SPL). A 2 × 3 repeated-measures ANOVA was used to determine the significance of the main and interaction effects. USLLs increased in the presence of background noise, regardless of the measurement approach used. However, the listening levels estimated by the participants using the survey and self-report field measure were significantly lower than those recorded using in-ear laboratory measurements by 9.6 and 3.3 dBA respectively. In-ear laboratory measures yielded the highest listening levels. Higher listening levels were observed in the presence of background noise for all measurement approaches. It appears that subjects' survey responses underestimate true listening levels in comparison to self-report calibrated field measures, and that both underestimate listening levels measured in the laboratory setting. More research in this area is warranted to determine whether measurement techniques can be refined and adjusted to accurately reflect real-world listening preferences.
Related Concept Videos
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated....
Interval Level of Measurement
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between...
Drug Concentrations: Measurements
Plasma...
Uncertainty in Measurement: Reading Instruments
Ordinal Level of Measurement
Data measured using an ordinal scale are similar to nominal scale data, but there is one major difference. The ordinal scale data can be ordered. An example of ordinal scale data is a list of the top five national parks...

