Aim:
To compare and correlate optic nerve head parameters obtained by Heidelberg retina tomograph (HRT) with short-wavelength automatic perimetry (SWAP) indices in eyes with ocular hypertension (OHT).
Methods:
One hundred and forty-six patients with OHT included in the present study. All subjects had reliable SWAP and HRT measurements performed within a 2wk period. The eyes were classified as normal/abnormal according to visual field criteria and Moorfields regression analysis (MRA). Correlations between visual field indices and HRT parameters were analyzed using Pearson correlation coefficient (r).
Results:
Twenty-nine eyes (19.9%) had SWAP defects. Twenty-nine eyes (19.9%) were classified as abnormal according to global MRA. Six eyes (4.1%) had abnormal global MRA and SWAP defects. The k statistic is 0.116 (P=0.12) indicating a very poor agreement between the methods. No statistical significant correlation between HRT and SWAP parameters was detected.
Conclusion:
SWAP defects may coexist with abnormalities of optic disc detected by HRT in eyes with OHT. In most eyes, however, the two methods detect different glaucoma properties.