Related Experiment Video
Updated: Mar 30, 2026

Physiology Lab Demonstration: Glomerular Filtration Rate in a Rat
Published on: July 26, 2015
Is the new GFR equation using inulin clearance a more accurate method for Asian patients?
Beom Seok Kim1, Yong Kyu Lee, Hoon Young Choi
1Department of Nephrology, Severance Hospital, Yonsei University College of Medicine, Seoul, Nephrology Division, Department of Internal Medicine, National Health Institute Corporation, Ilsan Hospital, Goyang, Geonggido, Nephrology Division, Department of Internal Medicine, Kangnam Severance Hospital, Seoul, Nephrology Division, Department of Internal Medicine, Yonsei University Wonju Christian Hospital, Wonju, Kangwon, Nephrology Division, Department of Internal Medicine, Chungnam National University Hospital, Daejeon, Nephrology Division Department of Internal Medicine, Inje University Busan Hospital, Busan, Nephrology Division, Department of Internal Medicine, Kyungpook National University Hospital, Daegu, Korea, Department of Nephrology, Nagoya University Graduate School of Medicine, Nagoya, Nakayamadera Imai Clinic, Takarazuka, Hyogo, Department of Functional Diagnostic Science, Osaka University Graduate School of Medicine, Osaka, and Department of Nephrology, Juntendo University School of Medicine, Tokyo, Japan.
Abstract:
Recently, a new glomerular filtration rate (GFR) equation for the Japanese population was proposed using measured inulin clearance. To expand its applicability to other Asian populations, we performed a comparative study in the Korean population. Inulin clearance was measured in 166 patients from seven participating medical centers in Korea. Patient's sera and urine were collected, and baseline clinical characteristics were measured to provide an estimated GFR (eGFR) by the Japanese GFR equation using inulin clearance (Japanese-GFR equation), the Modification of Diet in Renal Disease (MDRD) study equation, and the Chronic Kidney Disease - Epidemiology Collaboration (CKD-EPI) equation. We compared the results to determine which equation best estimated the measured GFR (mGFR). Accuracy (95% CI) within 30% of mGFR by the Japanese-GFR equation, the CKD-EPI equation and the MDRD study equation were 66 (58 - 72), 51 (43 - 58), and 55 (47 - 62)%, respectively. Bias (mGFR minus eGFR) were 3.4 ± 22.4, -12.0 ± 22.1, and -9.7 ± 23.8 mL/min/1.73 m2, respectively. The accuracy of the Japanese-GFR equation was significantly better than MDRD study equation in subjects with mGFR < 60 mL/min/1.73 m2 and in total subjects. The bias of the Japanese-GFR equation was significantly smaller compared with other two equations in total subjects. The Japanese-GFR equation has a higher accuracy with less bias than the other equations in estimating GFR in Korean populations. Further studies are required to determine if the current Japanese-GFR equation could represent the standard eGFR for other Asian populations.
Related Concept Videos
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Renal Drug Excretion: Glomerular Filtration
Drugs gain access to the kidney via the renal artery, which progressively branches off into afferent arterioles....

