Effect of iterative reconstruction on variability and reproducibility of epicardial fat volume quantification by
Seitaro Oda1, Daisuke Utsunomiya1, Yoshinori Funama2
1Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556, Japan.
Background:
The epicardial fat volume (EFV) measured by cardiac CT has emerged as an important parameter for understanding the pathophysiology of coronary atherosclerosis.
Objective:
We investigated the variability and reproducibility of EFV measurements and evaluated the effect of model-based type iterative reconstruction (M-IR) on measurement results.
Methods:
Non-contrast cardiac CT data (tube voltage 120-kVp, tube current time product 32 mAs) of 30 consecutive patients were reconstructed with filtered back projection (FBP), hybrid type iterative reconstruction (H-IR), and M-IR using a slice thickness of 3.0 mm. CT attenuation and image noise was measured for all reconstructions. Two observers independently quantified EFV using semi-automated software and interobserver agreement was evaluated.
Results:
There was no significant difference in the CT attenuation of the ascending aorta among the three reconstructions. The mean image noise on FBP-, H-IR-, and M-IR images was 48.0 ± 7.9 HU, 29.6 ± 4.8 HU, and 9.3 ± 1.3 HU, respectively; there was a significant difference among all comparison combinations for the three reconstructions (p < 0.01). FBP yielded the highest EFV among the three reconstructions (171.0 ± 54.9 cm(3) [FBP], 153.8 ± 53.1 cm(3) [H-IR], and 134.0 ± 46.4 cm(3) [M-IR]). For all three reconstructions, interobserver correlations were excellent (r = 0.91 [FBP], 0.93 [H-IR], and 0.96 [M-IR]). Interobserver comparisons showed that the lowest Bland-Altman limit of agreement was with M-IR (mean difference 2.0 ± 4.9%, 95% limit of agreement, -24.0 to 28.0%) followed by H-IR (-2.6 ± 7.1%, -39.8 to 34.6%) and FBP (-0.2 ± 8.6%, -45.3- to 45.0%).
Conclusion:
For the quantification of epicardial fat by cardiac CT, model-based iterative reconstruction can improve the image quality and lessen measurement variability.
More Related Videos
06:34Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...