Related Experiment Video
Updated: Mar 30, 2026

Extraction of Organochlorine Pesticides from Plastic Pellets and Plastic Type Analysis
Published on: July 1, 2017
An alternative clean-up column for the determination of polychlorinated biphenyls in solid matrices
Elizabeth N Ndunda1, Vincent O Madadi2, Boris Mizaikoff1
1Institute of Analytical and Bioanalytical Chemistry, University of Ulm, Albert-Einstein-Allee 11, 89081 Ulm, Germany. boris.mizaikoff@uni-Ulm.de.
Abstract:
The need for continuous monitoring of polychlorinated biphenyls (PCBs) has necessitated the development of analytical techniques that are sensitive and selective with minimal reagent requirement. In light of this, we developed a column for clean-up of soil and sediment extracts, which is less demanding in terms of the amount of solvent and sorbent. The dual-layer column consists of acidified silica gel and molecularly imprinted polymers (MIPs). MIPs were synthesized via aqueous suspension polymerization using PCB 15 as the dummy template, 4-vinylpyridine as the functional monomer and ethylene glycol dimethacrylate as the cross-linker and the obtained particles characterized via SEM, BET, and batch rebinding assays. Pre-concentration of the spiked real-world water sample using MISPE gave recoveries between 85.2 and 104.4% (RSD < 8.69). On the other hand, the specific dual-layer column designed for clean-up of extracts from complex matrices provided recoveries of 91.6-102.5% (RSD < 4%) for spiked soil, which was comparable to clean-up using acidified silica (70.4-90.5%; RSD < 3.72%) and sulfoxide modified silica (89.7-103.0%; RSD < 13.0%). However, the polymers were reusable maintaining recoveries of 79.8-111.8% after 30 cycles of regeneration and re-use, thereby availing a cost-effective clean-up procedure for continuous monitoring of PCBs. Method detection limits were 0.01-0.08 ng g(-1) and 0.002-0.01 ng mL(-1) for solid matrices and water, respectively.
More Related Videos
09:39Physical, Chemical and Biological Characterization of Six Biochars Produced for the Remediation of Contaminated Sites
Published on: November 28, 2014
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Related Concept Videos
Principles Of Column Chromatography
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Types Of Column Chromatography
Gel Filtration Chromatography
When the...