Related Experiment Video
Updated: Mar 30, 2026

Author Spotlight: Advancing Biopsy Techniques with Transesophageal Ultrasound
Published on: November 21, 2023
A meta-analysis comparing ProCore and standard fine-needle aspiration needles for endoscopic ultrasound-guided tissue
Ji Young Bang1, Robert Hawes2, Shyam Varadarajulu2
1Division of Gastroenterology and Hepatology, Indiana University, Indianapolis, Indiana, United States.
Background And Study Aims:
To overcome the limitations associated with cytology, a uniquely designed needle (ProCore) was introduced in an effort to obtain a core of tissue under endoscopic ultrasound (EUS) guidance. However, studies comparing the sample quality between ProCore and standard-design fine-needle aspiration (FNA) needles have yielded varying results. A systematic review and meta-analysis was therefore conducted to compare the performance of the ProCore and standard FNA needles when performing EUS-guided tissue acquisition.
Patients And Methods:
MEDLINE and EMBASE were searched to identify all published manuscripts that compared the ProCore needle with standard FNA needles. Noncomparative and technical feasibility studies were excluded. The main outcome measures were diagnostic adequacy, diagnostic accuracy, acquisition of histological core tissue, and mean number of passes required to achieve a diagnosis when sampling solid lesions.
Results:
Nine studies (total 576 patients) met the inclusion criteria. There was no significant difference in diagnostic adequacy (75.2 % vs. 89.0 %, odds ratio [OR] 0.39, P = 0.23), diagnostic accuracy (85.8 % vs. 86.2 %, OR 0.88, P = 0.53) or rate of histological core specimen acquisition (77.7 % vs. 76.5 %, OR 0.94, P = 0.85) between the ProCore and standard FNA needles, respectively. The mean number of passes required for diagnosis, however, was significantly lower when using the ProCore needle (standardized mean difference - 1.2, P < 0.001).
Conclusions:
Current data do not demonstrate a significant difference between the ProCore and standard FNA needles for sample adequacy, diagnostic accuracy or acquisition of a core specimen. However, the ProCore needle establishes the diagnosis with fewer passes.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...

