Analysis of PVC plasticizers in medical devices and infused solutions by GC-MS
Daniel Bourdeaux1, Mouloud Yessaad2, Philip Chennell1
1CHU Clermont-Ferrand, Pôle Pharmacie, Rue Montalembert, 63003 Clermont-Ferrand, France; Clermont Université, Université d'Auvergne, EA 4676C-BIOSENSS, 63000 Clermont-Ferrand, France.
Abstract:
In 2008, di-(2-ethylhexyl) phthalate (DEHP), was categorized as CMR 1B under the CLP regulations and its use in PVC medical devices (MD) was called into question by the European authorities. This resulted in the commercialization of PVC MDs plasticized with the DEHP alternative plasticizers tri-octyl trimellitate (TOTM), di-(2-ethylhexyl) terephthalate (DEHT), di-isononyl cyclohexane-1,2-dicarboxylate (DINCH), di-isononyl phthalate (DINP), di-(2-ethylhexy) adipate (DEHA), and Acetyl tri-n-butyl citrate (ATBC). The data available on the migration of these plasticizers from the MDs are too limited to ensure their safe use. We therefore developed a versatile GC-MS method to identify and quantify both these newly used plasticizers and DEHP in MDs and to assess their migration abilities in simulant solution. The use of cubic calibration curves and the optimization of the analytical method by an experimental plan allowed us to lower the limit of plasticizer quantification. It also allowed wide calibration curves to be established that were adapted to this quantification in MDs during migration tests, irrespective of the amount present, and while maintaining good precision and accuracy. We then tested the developed method on 32 PVC MDs used in our hospital and evaluated the plasticizer release from a PVC MD into a simulant solution during a 24h migration test. The results showed a predominance of TOTM in PVC MDs accompanied by DEHP (<0.1% w/w), DEHT, and sometimes DEHA. The migration tests showed a difference in the migration ability between the plasticizers and a non-linear kinetic release.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Plasticizers
Plasticizers function by using surface-active agents to create repulsive electrostatic forces between cement particles. This dispersion enhances the concrete's...
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...