M Loya1, L H Sanín2, P R González3
1Facultad de Odontología, Universidad Autónoma de Chihuahua, Ciudad Universitaria Campus 1. Avenida Universidad s/n, C.P. 31000 Chihuahua, Chih., Mexico.
Abstract:
Exposure among dentistry students has not been assessed or regulated in Mexico. This work assessed the average exposure of 35 dentistry students during their training with the aid of LiF:Mg,Cu,P+PTFE thermoluminescent dosimeters. For the students in the roles of dentist and observers, maximum accumulated equivalent dose obtained was 2.59±0.11 and 4.64±0.39 mSv, respectively. Students in the role as patients received a maximum accumulated effective dose of 28.41±0.31 mSv. If compared to occupational dose limits, this latter value is 56% of the recommended value of 50 mSv in any year. It was found that in all cases, values of equivalent dose to the women breasts were equal to the background dose. Results are discussed and compared to previous published work. Suggested recommendations were given to authorities in order to minimize exposure of the students in the role as patients.