Related Experiment Video
Updated: Mar 30, 2026

Utilizing a Reconfigurable Maze System to Enhance the Reproducibility of Spatial Navigation Tests in Rodents
Published on: December 2, 2022
An automated Y-maze based on a reduced instruction set computer (RISC) microcontroller for the assessment of
Francisco J Heredia-López1, Fernando J Álvarez-Cervera1, José G Collí-Alfaro1
1Departamento de Neurociencias, Centro de Investigaciones Regionales "Dr. Hideyo Noguchi", Universidad Autónoma de Yucatán, Avenida Itzáes No. 490 x 59, Mérida, Yucatán, México, 97000.
Abstract:
Continuous spontaneous alternation behavior (SAB) in a Y-maze is used for evaluating working memory in rodents. Here, the design of an automated Y-maze equipped with three infrared optocouplers per arm, and commanded by a reduced instruction set computer (RISC) microcontroller is described. The software was devised for recording only true entries and exits to the arms. Experimental settings are programmed via a keyboard with three buttons and a display. The sequence of arm entries and the time spent in each arm and the neutral zone (NZ) are saved as a text file in a non-volatile memory for later transfer to a USB flash memory. Data files are analyzed with a program developed under LabVIEW® environment, and the results are exported to an Excel® spreadsheet file. Variables measured are: latency to exit the starting arm, sequence and number of arm entries, number of alternations, alternation percentage, and cumulative times spent in each arm and NZ. The automated Y-maze accurately detected the SAB decrease produced in rats by the muscarinic antagonist trihexyphenidyl, and its reversal by caffeine, having 100 % concordance with the alternation percentages calculated by two trained observers who independently watched videos of the same experiments. Although the values of time spent in the arms and NZ measured by the automated system had small discrepancies with those calculated by the observers, Bland-Altman analysis showed 95 % concordance in three pairs of comparisons, while in one it was 90 %, indicating that this system is a reliable and inexpensive alternative for the study of continuous SAB in rodents.
More Related Videos
09:43A Fully Automated Rodent Conditioning Protocol for Sensorimotor Integration and Cognitive Control Experiments
Published on: April 15, 2014
17:45T-maze Forced Alternation and Left-right Discrimination Tasks for Assessing Working and Reference Memory in Mice
Published on: February 26, 2012