Related Experiment Video
Updated: Mar 30, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Accuracy of a Simple Digital Templating in Primary Uncemented Total Hip Arthroplasty
Hai-bo Si1, Yi Zeng1, Fei Cao1
1Department of Orthopaedics, West China Hospital, Sichuan University, Chengdu 610041, China.
Objective:
To introduce a simple preoperative digital templating in uncemented total hip arthroplasty (THA) and to determine its accuracy for preoperative size selection of the prostheses.
Methods:
A prospective study of digital planned THAs was performed on 90 hips with different types of prostheses from August 2013 to Angust 2014. The plastic templates of different types of prostheses were scanned for desired digital templating and the scanned images were then processed to the transparent, digital templates using Photoshop software. We calibrated the scales of the digital templates with the preoperative radiographs, and then selected the right size of the component. The preoperatively digital planned component sizes were compared to the actual sizes used in the operation, as well as the preoperatively traditional planned sizes.
Results:
In either cup or stem templating, no difference was found among the groups with different types of prostheses, and the accuracy of digital templating was statistically higher than traditional templating. In cup templating, digital planned and implanted cup sizes were identical in 43.33% of the cases, 78.89% of the cup sizes were predicted within 1 size (± 2mm) and 95.56% were predicted within 2 sizes (± 4 mm), all significantly higher than the results of traditional planned sizes (30.00%, P=0.044; 61.11%, P=0.007; 82.22%, P=0.004). The exact femoral stem size was predicted in 40.00% of cases using the digital templating, 84.44% of stem sizes were predicted within 1 size, and 93.33% within 2 sizes, better than using traditional templating (25.56%, P=0.028; 53.33%, P<0.001; 77.77%, P=0.003).
Conclusion:
This simple digital preoperative templating is an accurate and reproducible process to preoperatively predict the implant size of uncemented THA.