Related Experiment Video
Updated: Mar 30, 2026

07:17
Single Port Donor Nephrectomy
Published on: March 12, 2011
53.2K
Transumbilical pure single-port laparoscopic donor nephrectomy.
Joo Mee Kim1, Won Jun Jeong1, Byung Jo Choi1
1Department of Surgery, Daejeon St. Mary's Hospital, The Catholic University of Korea College of Medicine, Daejeon, Korea.
Annals of Surgical Treatment and Research
|November 18, 2015
Summary
Transumbilical single-port laparoscopic donor nephrectomy (SPLDN) offers a minimally invasive approach to kidney transplantation with cosmetic benefits and faster recovery. This technique demonstrates safety and efficacy comparable to traditional methods in initial case studies.
Area of Science:
- Minimally Invasive Surgery
- Transplantation Surgery
- Urology
Background:
- Transumbilical single-port laparoscopic donor nephrectomy (SPLDN) is an emerging technique in kidney transplantation.
- It aims to reduce surgical trauma and improve cosmetic outcomes compared to conventional methods.
Observation:
- The umbilicus served as the single port for laparoscopic instruments and specimen retrieval.
- Two successful cases of transumbilical SPLDN were performed at Daejeon St. Mary's Hospital.
Findings:
- Operating times were 230 and 265 minutes, with no intra- or postoperative complications.
- Wound lengths were 4 cm and 2.5 cm, with hospitalization durations of 2 and 1 day, respectively.
- The technique proved effective for graft retrieval, meeting standard requirements.
Implications:
- Transumbilical SPLDN presents a viable, minimally invasive option for kidney donation.
- This approach offers significant advantages in terms of patient recovery and aesthetics.
- Further research and adoption by experienced surgeons can expand its clinical utility.