Comparison between invasive and non-invasive blood pressure in young, middle and old age
Bing Liu1, Qiao Li2, Peng Qiu3
1a Department of Cardiology , Jinan Fourth Hospital , Jinan , Shandong , PR China ;
Abstract:
We aimed to compare simultaneous invasive and non-invasive blood pressure (IBP and NIBP) measurements in young, middle and old age using the data from the Multiparameter Intelligent Monitoring in Intensive Care II (MIMIC II) database. In total, 23,679 blood pressure measurements were extracted from 742 patients, divided into three groups of young, middle and old age. IBP-NIBP differences in systolic/diastolic blood pressure (SBP/DBP) were 0.1 ± 16.5 mmHg/11.0 ± 12.2 mmHg in young age, -2.9 ± 19.8 mmHg/6.9 ± 17.5 mmHg in middle age and -3.2 ± 29.3 mmHg/8.5 ± 19.8 mmHg in old age. The mean and standard deviation (SD) of invasive systolic blood pressure (ISBP)-non-invasive systolic blood pressure (NISBP) differences increased from young to middle then to old age, and the SD of invasive diastolic blood pressure (IDBP)-non-invasive diastolic blood pressure (NIDBP) differences also increased with age. In young, middle and old age, the correlation coefficients were 0.86, 0.79 and 0.53, respectively, between ISBP and NISBP, and 0.78, 0.78 and 0.41 between IDBP and NIDBP. In conclusion, IBP showed good correlation with NIBP in each age category. The agreement between IBP and NIBP measurements was influenced by age category.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Pre-Procedural Guidelines for Assessing Blood Pressure