Related Experiment Video
Updated: Mar 30, 2026

Monitoring of Systemic and Hepatic Hemodynamic Parameters in Mice
Published on: October 4, 2014
Hemodynamic monitoring: To calibrate or not to calibrate? Part 1--Calibrated techniques
Yannick Peeters, Jelle Bernards, Michaël Mekeirele
1Intensive Care Unit and High Care Burn Unit, Ziekenhuis Netwerk Antwerpen, ZNA Stuivenberg, Antwerpen, Belgium. manu.malbrain@skynet.be.
Abstract:
Over recent decades, hemodynamic monitoring has evolved from basic cardiac output monitoring techniques to a broad variety of sophisticated monitoring devices with extra parameters. In order to reduce morbidity and mortality and optimize therapeutic strategies, different monitoring techniques can be used to guide fluid resuscitation and other medical management. Generally, they can be divided in calibrated and non-calibrated techniques. In the first part of this review, the available calibrated techniques, ranging from invasive to non-invasive, will be discussed. We performed a review of the literature in order to give an overview of the current hemodynamic monitoring devices. For each monitoring system, a short overview of the physical principles, the advantages and disadvantages and the available literature with regard to validation is given. Currently, many promising hemodynamic monitoring devices are readily available in order to optimize therapeutic management in both perioperative and ICU settings. Although several of these calibrated techniques have been validated in the literature, not all techniques have been shown to reduce morbidity and mortality. Many new techniques, especially some non-calibrated devices, lack good validation data in different clinical settings (sepsis, trauma, burns, etc.). The cardiac output values obtained with these techniques need therefore to be interpreted with caution as will be discussed in the second part of this concise review. Transthoracic echocardiography forms a good initial choice to assess hemodynamics in critically ill patients after initial stabilisation. However in complex situations or in patients not responding to fluid resuscitation alone, advanced hemodynamic monitoring is recommended with the use of calibrated techniques like transpulmonary thermodilution. Calibrated techniques are preferred in patients with severe shock and changing conditions of preload, afterload and contractility. The use of the pulmonary artery catheter should be reserved for patients with right ventricular failure in order to assess the effect of medical treatment.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessment of blood pressure in brachial artery(two-step method)