Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Comparison of left ventricular manual versus automated derived longitudinal strain: implications for clinical
Yukari Kobayashi1,2, Miyuki Ariyama3,4, Yuhei Kobayashi3,4
1Division of Cardiovascular Medicine, Stanford University School of Medicine, 300 Pasteur Drive Room H2170, Stanford, CA, 94305, USA. yukariko@stanford.edu.
Abstract:
Systolic global longitudinal strain (GLS) is emerging as a useful metric of ventricular function in heart failure and usually assessed using post-processing software. The purpose of this study was to investigate whether longitudinal strain (LS) derived using manual-tracings of ventricular lengths (manual-LS) can be reliable and time efficient when compared to LS obtained by post-processing software (software-LS). Apical 4-chamber view images were retrospectively examined in 50 healthy controls, 100 patients with dilated cardiomyopathy (DCM), and 100 with hypertrophic cardiomyopathy (HCM). We measured endocardial and mid-wall manual-LS and software-LS, using peak of average regional curve [software-LS(a)] and global ventricular lengths [software-LS(l)] according to definition of Lagragian strain. We compared manual-LS and software-LS by using Bland-Altman plot and coefficient of variation (COV). In addition, test-retest was also performed for further assessment of variability in measurements. While manual-LS was obtained in all subjects, software-LS could be obtained in 238 subjects (95%). The time spent for obtaining manual-LS was significantly shorter than for the software-LS (94 ± 39 s vs. 141 ± 79 s, P < 0.001). Overall, manual-LS had an excellent correlation with both software-LS (a) (R(2) = 0.93, P < 0.001) and software-LS(l) (R(2) = 0.84, P < 0.001). The bias (95%CI) between endocardial manual-LS and software-LS(a) was 0.4% [-2.8, 3.6%] in absolute and 3.5% [-17.0, 24.0%] in relative difference while it was 0.4% [-2.5, 3.3%] and 3.4% [-16.2, 23.1%], respectively with software-LS(l). Mid-wall manual-LS and mid-wall software-LS(a) also had good agreement [a bias (95% CI) for absolute value of 0.1% [-2.1, 2.5%] in HCM, and 0.2% [-2.2, 2.6%] in controls]. The COV for manual and software derived LS were below 6%. Test-retest showed good variability for both methods (COVs were 5.8 and 4.7 for endocardial and mid-wall manual-LS, and 4.6 and 4.9 for endocardial and mid-wall software-LS(a), respectively. Manual-LS appears to be as reproducible as software-LS; this may be of value especially when global strain is the metric of interest.
More Related Videos
06:34Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010