Related Experiment Video
Updated: Mar 30, 2026

Establishment of Deep Hypothermic Circulatory Arrest in Rats
Published on: December 16, 2022
The Use of Extracorporeal Membrane Oxygenation Systems in Severe Accidental Hypothermia After Drowning: A Centre
Matthias Weuster1, Assad Haneya, Bernd Panholzer
1From the *Department of Trauma Surgery, †Department of Cardiovascular Surgery, University Hospital Schleswig-Holstein, Campus Kiel, Kiel, Germany; ‡Naval Institute of Maritime Medicine, Kronshagen, Germany; and §Department of Intensive Care Medicine, Imland Klinik, Rendsburg, Germany.
Abstract:
Cardiopulmonary failure because of drowning with accidental hypothermia (AH) remains a major task for emergency care physicians. In this case series, we describe our experience in nine patients with cardiopulmonary failure after drowning with AH less than 35°C, who were provided on an emergency basis with extracorporeal life support (ECLS) system or extracorporeal membrane oxygenation (ECMO). Conservative rewarming methods are not considered for this study. Preclinical conditions and protocols were gathered. Surgical reports and clinical data sets were collected. Median age was 24 years (range, 6-75 years). Six patients were male. Climatic conditions mostly showed cold to frosty weather. All cases had different preclinical rescue procedures. They reached the emergency department under cardiopulmonary resuscitation (CPR). Indications for ECLS were cardiac arrest, and in one case, pulmonary failure. Mean CPR duration was 60 min (range: 15-120 min). Before implantation, the median pH value was 6.9. Two patients could be successfully weaned from the systems. Cause of death was severe neurologic damage in six patients and cardiac failure in one patient. The use of ECLS/ECMO is a therapy option for a small range of patients with cardiopulmonary failure because of drowning with AH. Nevertheless, the interval of preclinical rescue remains extensively long.
Related Concept Videos
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-III
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-IV
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration