Related Experiment Video
Updated: Mar 30, 2026

Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
THE EFFECT OF RADIATION SHIELDS ON OPERATOR EXPOSURE DURING CONGENITAL CARDIAC CATHETERISATION
Sarosh P Batlivala1,2,3,4, Dennise Magill5, Marc A Felice5
1Division of Cardiology, The Children's Hospital of Philadelphia, Philadelphia, PA, USA.
Abstract:
Cardiac catheterisation personnel are exposed to occupational radiation and its health risks. Little data exist regarding the efficacy of radiation-protective equipment from congenital catheterisation laboratories (CLs). The authors retrospectively reviewed data in which CL operators wore a radiation dosemeter during catheterizations on patients of >20 kg. A leaded under-table skirt was present in all cases. Three additional radiation-protective devices were utilised at operator discretion: a top extension to the under-table skirt, a ceiling-mounted shield and a disposable patient drape. Case details, operator position, fluoroscopy time, incident air KERMA in the patient plane (K, mGy) and dose-area product (DAP, µGy·m2) were recorded. A total of 136 catheterizations over 8 months were included. Median operator dose (OpD) was 12 µSv (range 0-930) and indexed to K and DAP to correct for patient factors and case times. Indexed OpD decreased significantly with each additional shield used (14.8 vs. 1.3 nSv µGy-1 m-2 and 124 vs. 14 nSv mGy-1 with one and four shields, respectively, p < 0.001). This trend was not significant with operator at head-of-bed. Combinations that included the ceiling shield had the lowest indexed OpD. The patient drape did not further reduce OpD when all other shields were used (1.3 vs. 2.2 nSv µGy-1 m-2, p = 0.5; 14 vs. 17 nSv mGy-1, p = 0.4) and was associated with higher patient exposure indexed to weight and fluoroscopy time (4.5 vs. 3.1 µGy m2 kg-min-1, p = 0.009; and 0.51 vs. 0.38 mGy kg-min-1, p = 0.01). Supplemental radiation barriers can decrease operator-absorbed radiation. A ceiling-mounted shield may provide greatest benefit. The authors do not recommend routine use of disposable patient drapes.
More Related Videos
08:30X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization IV: Nursing Management
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization II: Right Heart Catheterization