Related Experiment Video
Updated: Mar 30, 2026

Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
Use of neonatal simulation models to assess competency in bag-mask ventilation
S A Pearlman1,2, S C Zern3, T Blackson4
1Division of Neonatology, Department of Pediatrics, Christiana Care Health System, Newark, DE, USA.
Objective:
Providing adequate bag-mask ventilation (BMV) is an essential skill for neonatal resuscitation. Often this skill is learned using simulation manikins. Currently, there is no means of measuring the adequacy of ventilation in simulated scenarios. Thus, it is not possible to ascertain proficiency. The first aim of this study was to measure the pressure generated during BMV as performed by providers with different skill levels and measure the impact of different feedback mechanisms. The second aim was to measure the pressure volume characteristics of two neonatal manikins to see how closely they reflect newborn lung mechanics.
Study Design:
In Phase I to achieve the first aim, we evaluated BMV skills in different level providers including residents (n=5), fellows (n=5), neonatal nurse practitioners (n=5) and neonatologists (n=5). Each provider was required to provide BMV for 2-min epochs on the SimNewB (Laerdal), which had been instrumented to measure pressure-volume characteristics. In sequential 2-min epochs, providers were given different feedback including chest-wall movement alone compared to manometer plus chest-wall movement or chest-wall movement plus manometer plus laptop lung volume depiction. In Phase II of the study we measured pressure-volume characteristics in instrumented versions of the SimNewB (Laerdal) and NeoNatalie (Laerdal).
Results:
In Phase I, all providers are compared with the neonatologists. All measurements of tidal volume (Vt) are below the desired 5 ml kg(-1). The greatest difference in Vt between the neonatologists and other providers occurs when only chest-wall movement is provided. A linear relationship is noted between Vt and PIP for both SimNewB and NeoNatalie. The compliance curves are not 'S-shaped' and are different between the two models (P<0.001).
Conclusion:
Phase I of this study demonstrates that the SimNewB with the feedback of chest-wall movement alone was the best method of distinguishing experienced from inexperienced providers during simulated BMV. Therefore this is likely to be the best method to ascertain proficiency. Phase II of the study shows that the currently available neonatal simulation manikins do not have pressure-volume characteristics that are reflective of newborn lung mechanics, which can result in suboptimal training.
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...