Objective:
Fluorine-18 fluorodeoxyglucose (FDG)-positron emission tomography (PET) and PET/computed tomography (PET/CT) have had a considerable impact on the detection of various malignancies. PET and PET/CT are minimally invasive methods that can provide whole-body imaging at one time. Therefore, an FDG-PET cancer screening program has been widely used in Japan. However, the breast cancer detection rate of FDG-PET cancer screening is relatively low. Therefore, FDG-PET screening is not recommended for breast cancer screening. Positron emission mammography (PEM) is a high-resolution molecular breast imaging technology. PEM can detect small breast cancers that cannot be detected on PET or PET/CT images due to limited spatial resolution. We have performed opportunistic breast cancer screening using PEM since 2011. To the best of our knowledge, this is the first report regarding PEM breast cancer screening.
Methods:
This study enrolled 265 women. PEM images were analyzed by agreement of 2 experienced nuclear medicine physicians. The readers were given information from medical interview sheet. US findings were interpreted holistically. The number of participants, patient recall rate, further examination rate, and cancer detection rate by year were calculated.
Results:
The overall recall rate was 8.3%; the work-up examination rate was 77.3%, and cancer detection rate was 2.3%. The positive predictive value of PEM was 27.3%. Six cancers were found by PEM screening. Five were invasive cancers and one was ductal carcinoma in situ. Histological tumor sizes were reported in three cases: 0.7, 1.2, and 2 cm.
Conclusion:
PEM screening appears to have potential for breast cancer screening.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET