Objective:
The purpose of this study was to compare wide-volume and helical pediatric 320-MDCT of the chest with respect to radiation dose and image quality.
Materials And Methods:
From November 2012 to September 2013, 59 wide-volume and 47 helical pediatric chest 320-MDCT images were obtained. The same tube potential and effective tube current-time product were applied in the two groups according to patient weight (group A, < 10 kg, n = 18; group B, 10-19.9 kg, n = 60; group C, 20-39.9 kg, n = 28). To compensate for overranging, adjusted CT dose index (CTDI) was calculated by dividing dose-length product (DLP) by the scan ranges imaged. Adjusted CTDI, DLP, overall image quality, motion artifact, noise, and scan ranges were compared by Mann-Whitney U test or t test.
Results:
The adjusted CTDI was significantly lower in the group who underwent wide-volume CT than in the group who underwent helical CT (weight group A, p < 0.001; group B, p < 0.001; group C, p = 0.003). The DLP was lower in the wide-volume group than in the helical CT group in weight groups A (p < 0.001) and B (p < 0.001) but not in group C (p = 0.162). All CT scans were of diagnostic quality, and there was no significant difference between the wide-volume and helical CT groups (p = 0.318). The motion artifact score was significantly higher in the wide-volume group than in the helical CT group in groups B (p < 0.001) and C (p = 0.010) but not in group A (p = 0.931). The noise was significantly lower in the wide-volume group than in the helical CT group (p < 0.001).
Conclusion:
In pediatric chest CT, use of wide-volume CT can decrease radiation exposure while preserving image quality. It is associated with less noise than helical CT but may be subject to more motion artifact.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT