Related Experiment Video
Updated: Mar 29, 2026

Preparation, Purification, and Characterization of Lanthanide Complexes for Use as Contrast Agents for Magnetic Resonance Imaging
Published on: July 21, 2011
A Manganese Alternative to Gadolinium for MRI Contrast
Eric M Gale1, Iliyana P Atanasova1, Francesco Blasi1
1The Athinoula A. Martinos Center for Biomedical Imaging, The Institute for Innovation in Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School , 149 Thirteenth Street, Suite 2301, Charlestown, Massachusetts 02129, United States.
Abstract:
Contrast-enhanced computed tomography (CT) and magnetic resonance imaging (MRI) are routinely used to diagnose soft tissue and vascular abnormalities. However, safety concerns limit the use of iodinated and gadolinium (Gd)-based CT and MRI contrast media in renally compromised patients. With an estimated 14% of the US population suffering from chronic kidney disease (CKD), contrast media compatible with renal impairment is sorely needed. We present the new manganese(II) complex [Mn(PyC3A)(H2O)](-) as a Gd alternative. [Mn(PyC3A)(H2O)](-) is among the most stable Mn(II) complexes at pH 7.4 (log KML = 11.40). In the presence of 25 mol equiv of Zn at pH 6.0, 37 °C, [Mn(PyC3A)(H2O)](-) is 20-fold more resistant to dissociation than [Gd(DTPA)(H2O)](2-). Relaxivity of [Mn(PyC3A)(H2O)](-) in blood plasma is comparable to commercial Gd contrast agents. Biodistribution analysis confirms that [Mn(PyC3A)(H2O)](-) clears via a mixed renal/hepatobiliary pathway with >99% elimination by 24 h. [Mn(PyC3A)(H2O)](-) was modified to form a bifunctional chelator and 4 chelates were conjugated to a fibrin-specific peptide to give Mn-FBP. Mn-FBP binds the soluble fibrin fragment DD(E) with Kd = 110 nM. Per Mn relaxivity of Mn-FBP is 4-fold greater than [Mn(PyC3A)(H2O)](-) and increases 60% in the presence of fibrin, consistent with binding. Mn-FBP provided equivalent thrombus enhancement to the state of the art Gd analogue, EP-2104R, in a rat model of arterial thrombosis. Mn metabolite analysis reveals no evidence of dechelation and the probe was >99% eliminated after 24 h. [Mn(PyC3A)(H2O)](-) is a lead development candidate for an imaging probe that is compatible with renally compromised patients.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Imaging Studies III: Computed Tomography
Imaging Studies IV: Magnetic Resonance Imaging