Related Experiment Video
Updated: Mar 29, 2026

Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing
Published on: March 13, 2013
Polymer-coated micro-optofluidic ring resonator detector for a comprehensive two-dimensional gas chromatographic
William R Collin1, Kee W Scholten, Xudong Fan
1Department of Chemistry, University of Michigan, Ann Arbor, MI, 48109-1055, USA. ezellers@umich.edu.
Abstract:
We describe first results from a micro-analytical subsystem that integrates a detector comprising a polymer-coated micro-optofluidic ring resonator (μOFRR) chip with a microfabricated separation module capable of performing thermally modulated comprehensive two-dimensional gas chromatographic separations (μGC ×μGC) of volatile organic compound (VOC) mixtures. The 2 × 2 cm μOFRR chip consists of a hollow, contoured SiO(x) cylinder (250 μm i.d.; 1.2 μm wall thickness) grown from a Si substrate, and integrated optical and fluidic interconnection features. By coupling to a 1550 nm tunable laser and photodetector via an optical fiber taper, whispering gallery mode (WGM) resonances were generated within the μOFRR wall, and shifts in the WGM wavelength caused by transient sorption of eluting vapors into the PDMS film lining the μOFRR cylinder were monitored. Isothermal separations of a simple alkane mixture using a PDMS coated 1st-dimension ((1)D) μcolumn and an OV-215-coated 2nd-dimension ((2)D) μcolumn confirmed that efficient μGC ×μGC-μOFRR analyses could be performed and that responses were dominated by film-swelling. Subsequent tests with more diverse VOC mixtures demonstrated that the modulated peak width and the VOC sensitivity were inversely proportional to the vapor pressure of the analyte. Modulated peaks as narrow as 120 ms and limits of detection in the low-ng range were achieved. Structured contour plots generated with the μOFRR and a reference FID were comparable.
More Related Videos
Related Concept Videos
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...