Related Experiment Video
Updated: Mar 29, 2026

O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
Performance comparison of partial least squares-related variable selection methods for quantitative structure
Mohammad Talebi1, Georg Schuster1, Robert A Shellie1
1Australian Centre for Research on Separation Science (ACROSS), School of Physical Sciences, University of Tasmania, Hobart, Tasmania, Australia.
Abstract:
The relative performance of six multivariate data analysis methods derived from or combined with partial least squares (PLS) has been compared in the context of quantitative structure-retention relationships (QSRR). These methods include, GA (genetic algorithm)-PLS, Monte Carlo uninformative variable elimination (MC-UVE), competitive adaptive reweighted sampling (CARS), iteratively retaining informative variables (IRIV), variable iterative space shrinkage approach (VISSA) and PLS with automated backward selection of predictors (autoPLS). A set of 825 molecular descriptors was computed for 86 suspected sports doping compounds and used for predicting their gradient retention times in reversed-phase liquid chromatography (RPLC). The correlation between molecular descriptors selected by each technique and the retention time was established using the PLS method. All models derived from a selected subset of descriptors outperformed the reference PLS model derived from all descriptors, with very small demands of computational time and effort. A performance comparison indicated great diversity of these methods in selecting the most relevant molecular descriptors, ranging from 28 for CARS to 263 for MC-UVE. While VISSA provided the lowest degree of over-fitting for the training set, CARS demonstrated the best compromise between the prediction accuracy and the number of selected descriptors, with the prediction error of as low as 46s for the external test set. Only ten descriptors were found to be common for all models, with the characteristics of these descriptors being representative of the retention mechanism in RPLC.
More Related Videos
11:25Multi-step Preparation Technique to Recover Multiple Metabolite Compound Classes for In-depth and Informative Metabolomic Analysis
Published on: July 11, 2014
13:54A Workflow for Lipid Nanoparticle LNP Formulation Optimization using Designed Mixture-Process Experiments and Self-Validated Ensemble Models SVEM
Published on: August 18, 2023
Related Concept Videos
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Chromatographic Methods: Terminology
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...