Related Experiment Video
Updated: Mar 29, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Pre-Chemoradiotherapy FDG PET/CT cannot Identify Residual Metabolically-Active Volumes within Individual Esophageal
1Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, USA.
Objective:
To study whether subvolumes with a high pre-chemoradiotherapy (CRT) FDG uptake could identify residual metabolically-active volumes (MAVs) post-CRT within individual esophageal tumors. Accurate identification will allow simultaneous integrated boost to these subvolumes at higher risk to improve clinical outcomes.
Methods:
Twenty patients with esophageal cancer were treated with CRT plus surgery and underwent FDG PET/CT scans before and after CRT. The two scans were rigidly registered. Seven MAVs pre-CRT and four MAVs post-CRT within a tumor were defined with various SUV thresholds. The similarity and proximity between the MAVs pre-CRT and post-CRT were quantified with three metrics: fraction of post-CRT MAV included in pre-CRT MAV, volume overlap and centroid distance.
Results:
Eight patients had no residual MAV. Six patients had local residual MAV (SUV ≥2.5 post-CRT) within or adjoining the original MAV (SUV ≥2.5 pre-CRT). On average, less than 65% of any post-CRT MAVs was included in any pre-CRT MAVs, with a low volume overlap <45%, and large centroid distance >8.6 mm. In general, subvolumes with higher FDG-uptake pre-CRT or post-CRT had lower volume overlap and larger centroid distance. Six patients had new distant MAVs that were determined to be inflammation from radiation therapy.
Conclusions:
Pre-CRT PET/CT cannot reliably identify the residual MAVs within individual esophageal tumors. Simultaneous integrated boost to subvolumes with high FDG uptake pre-CRT may not be feasible.
More Related Videos
10:48PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...