Evaluation of the Kinetic Performance Differences between Hydrophilic-Interaction Liquid Chromatography and
Huiying Song1, Gert Desmet2, Deirdre Cabooter1
1Department for Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, KU Leuven , Herestraat 49, Leuven, Belgium.
Abstract:
A protocol using trifluoroacetic acid at a temperature of 60 °C is developed for the adequate removal of the stationary phase of reversed-phase liquid chromatography (RPLC) columns. This procedure allows for studying the same column first under RPLC and subsequently under hydrophilic-interaction liquid chromatography (HILIC) conditions to isolate intrinsic differences between mass transfer properties in HILIC and RPLC from differences in packing quality. The established procedure allows for a complete removal of the stationary phase (confirmed by retention studies and thermogravimetry analyses) while leaving the structure of the packing unaffected (witnessed by an unchanged external porosity and pressure drop). Accurate plate height analysis comparing compounds at the same zone retention factor indicates a significant difference in reduced c-term (typically 40-80% larger under HILIC conditions), despite the columns otherwise being identical. Correcting for the known contributions of longitudinal diffusion (b-term) and mass transfer (cm- and cs-term) to focus on band broadening originating from eddy dispersion, similar strong differences are observed (differences of some h = 0.3 up to 1.2). These findings show that the interior structure and retention mechanism of the particles have a very strong effect on the observed eddy dispersion, a factor typically ascribed to phenomena occurring outside the particles. This also implies that comparing the quality of packings of different particle types is virtually impossible without the availability of a sound model to correct for the intraparticle effect on the observed eddy dispersion.
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...