Related Experiment Video
Updated: Mar 29, 2026

Ultrafast Time-resolved Near-IR Stimulated Raman Measurements of Functional π-conjugate Systems
Published on: February 10, 2020
Basis Set Dependence of Vibrational Raman and Raman Optical Activity Intensities
James R Cheeseman1, Michael J Frisch1
1Gaussian Inc. , 340 Quinnipiac St., Bldg. 40, Wallingford, Connecticut 06492-4050, United States.
Abstract:
We present a systematic study of the basis set dependence of the backscattering vibrational Raman intensities and Raman Optical Activity (ROA) intensity differences. The accuracies of computed Raman intensities and ROA intensity differences for a series of commonly used basis sets are reported, relative to large reference basis sets, using the B3LYP density functional. This study attempts to separately quantify the relative accuracies obtained from particular basis set combinations: one for the geometry optimization and force field computation and the other for the computation of Raman and ROA tensors. We demonstrate here that the basis set requirements for the geometry and force fields are not similar to those of the Raman and ROA tensors. The Raman and ROA tensors require basis sets with diffuse functions, while geometry optimizations and force field computations typically do not. Eleven molecules were examined: (S)-methyloxirane, (S)-methylthirane, (R)-epichlorhydrin, (S)-CHFClBr, (1S,5S)-α-pinene, (1S,5S)-β-pinene, (1S,4S)-norborneneone, (M)-σ-[4]-helicene, an enone precursor to a cytotoxic sesquiterpene, the gauche-gauche conformer of the monosaccharide methyl-β-d-glucopyranose, and the dipeptide Ac-(alanine)2-NH2. For the molecules examined here, intensities and intensity differences obtained from Raman and ROA tensors computed using the aug-cc-pVDZ basis set are nearly equivalent to those computed with the larger aug-cc-pVTZ basis set. We find that modifying the aug-cc-pVDZ basis set by removing the set of diffuse d functions on all atoms (while keeping the diffuse s and p sets), denoted as aug(sp)-cc-pVDZ, results in a basis set which is significantly faster without much reduction in the overall accuracy. In addition, the popular rDPS basis set introduced by Zuber and Hug offers a good compromise between accuracy and efficiency. The combination of either the aug(sp)-pVDZ or rDPS basis for the computation of the Raman and ROA tensors with the 6-31G* basis set for the geometry optimization and force field calculation is a reliable and cost-effective method for obtaining Raman intensities and ROA intensity differences.
More Related Videos
08:54Vibrational Spectra of a N719-Chromophore/Titania Interface from Empirical-Potential Molecular-Dynamics Simulation, Solvated by a Room Temperature Ionic Liquid
Published on: January 25, 2020
07:44Resonance Raman Spectroscopy of Extreme Nanowires and Other 1D Systems
Published on: April 28, 2016
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
IR Spectrum Peak Intensity: Amount of IR-Active Bonds