Related Experiment Video
Updated: Mar 29, 2026

Doppler Optical Coherence Tomography of Retinal Circulation
Published on: September 18, 2012
Imaging of the internal nasal valve using long-range Fourier domain optical coherence tomography
Anna S Englhard1, Maximilian Wiedmann2, Georg J Ledderose1
1Department of Otolaryngology-Head and Neck Surgery, Ludwig Maximilian University Munich, Munich, Germany.
Objectives/Hypothesis:
To evaluate for the first time the feasibility and methodology of long-range Fourier domain optical coherence tomography (LR-OCT) imaging of the internal nasal valve (INV) area in healthy individuals.
Study Design:
Prospective individual cohort study.
Methods:
For 16 individuals, OCT was performed in each nare. The angle and the cross-sectional area of the INV were measured. OCT images were compared to corresponding digital pictures recorded with a flexible endoscope.
Results:
INV angle measured by OCT was found to be 18.3° ± 3.1° (mean ± standard deviation). The cross-sectional area was 0.65 ± 0.23 cm(2) . The INV angle measured by endoscopy was 18.8° ± 6.9°. There was no statistically significant difference between endoscopy and OCT concerning the mean INV angle (P = .778), but there was a significant difference in test precision (coefficient of variance 50% vs. 15%; P < .001).
Conclusions:
LR-OCT proved to be a fast and easily performed method. OCT could accurately quantify the INV area. The values of the angle and the cross-sectional area of the INV were reproducible and correlated well with the data seen with other methods. Changes in size could be reliably delineated. Endoscopy showed similar values but was significantly less precise.
Level Of Evidence:
2b. Laryngoscope, 126:E97-E102, 2016.
More Related Videos
12:22Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
Published on: August 4, 2018
12:54Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
Published on: October 2, 2021
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System IV: CMRI