Quantitation of Plasma Renin Activity in Plasma Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)
J Grace Van Der Gugten1,2, Daniel T Holmes3,4
1Department of Pathology and Laboratory Medicine, University of British Columbia, Rm. G227 - 2211 Wesbrook Mall, Vancouver, BC, V6T 2B5, Canada.
Abstract:
Accurate determination of plasma renin activity (PRA) is essential for the development and maintenance of an effective screening program for primary aldosteronism (PA). PRA measurement can also be useful in the investigation of renal artery stenosis, syndrome of mineralocorticoid excess, Addison's disease, congenital adrenal hyperplasia, Bartter and Gitelman syndromes, and for inherited defects in the renin angiotensin aldosterone system (RAAS). We describe a semi-automated and simple method for the accurate and precise measurement of PRA from 500 μL of plasma (250 μL if blank subtraction is omitted, as discussed) using a liquid chromatography and tandem mass spectrometry (LC-MS/MS) method for angiotensin I (AngI) in 96-well format. After a 3 h AngI generation step at 37 °C in buffering conditions at pH 6, the reaction is quenched with 10 % formic acid containing AngI internal standard. Sample preparation then proceeds with offline solid phase extraction, two wash steps, and methanol elution followed by injection into the LC-MS/MS system. Quantitation is performed against a 7-point calibration linear curve prepared in buffer. The assay calibration range is 0.34-30.0 ng/mL which corresponds to PRA values of 0.11-10.0 ng/mL/h: much wider than was possible using traditional competitive antibody-based methods. Total precision in clinical production has been observed to be 5.8 to 5.0 % for Bio-Rad Hypertension Control materials having nominal PRA values ranging from 1.73 to 12.43 ng/mL/h. At AngI concentrations of 0.06 ng/L (corresponding to a PRA of 0.02 ng/mL/h), signal to noise ratios are 50:1 indicating that the limit of quantitation is well below the level required for clinical use.
More Related Videos
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Renal Drug Clearance: Overview
Renal clearance can be calculated using different methods. One approach is to divide the urinary drug excretion rate by the plasma drug concentration. This method directly measures renal clearance, indicating the kidneys' efficiency in...
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...