Related Experiment Video
Updated: Mar 29, 2026

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Monomer conversion, microhardness, internal marginal adaptation, and shrinkage stress of bulk-fill resin composites
Bruna Marin Fronza1, Frederick Allen Rueggeberg2, Roberto Ruggiero Braga3
1Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, Av. Limeira, 901, Piracicaba 13414-903, SP, Brazil.
Objective:
To evaluate degree of conversion (DC), Knoop microhardness (KHN), internal marginal adaptation (IA), and polymerization shrinkage stress (PS) of one conventional and four bulk-fill composites.
Methods:
Bulk-fill composites tested were Surefil SDR (SDR), Filtek Bulk-Fill (FBF), Tetric EvoCeram Bulk-Fill (TEC), and EverX Posterior (EXP). The conventional composite Herculite Classic (HER) was tested using both incremental and bulk-fill insertion techniques. Standardized Class I preparations (4-mm-depth) were made in extracted molars and restored with each product system (N=5). After 1-week wet storage, restorations were cross-sectioned and DC and KHN were evaluated at four depths (1, 2, 3, and 4mm) using confocal Raman spectroscopy and KHN techniques, respectively. Epoxy resin replicas of restorations were evaluated using scanning electron microscopy for IA. PS was determined using composite bonded to acrylic rods attached to a universal testing machine (N=5).
Results:
Within bulk-fill products, only SDR and FBF demonstrated similar DC at all depths, and KHN values did not statistically differ among depths, except for TEC. Neither placement method nor depth affected KHN or DC, except the DC of HER bulk-fill at 4mm. Incrementally layered HER, and bulk-fills SDR and TEC demonstrated the lowest proportion of internal gaps. Highest and lowest PS values were measured for EXP and TEC, respectively.
Significance:
DC with depth was not uniform among all bulk-fill materials, although no difference in KHN was found. Higher PS correlated positively with higher proportion of interfacial gaps. The incremental technique using conventional composite showed reduced gap formation.
Related Concept Videos
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...
Microcracking in Concrete