Related Experiment Video
Updated: Mar 29, 2026

Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
[Usefulness for detection of inappropriate blood pressure variability using 'wearable blood pressure sensor']
Abstract:
In the clinical settings, it has frequently seen that the elderly have rapid blood pressure (BP) elevation and decline, leading to such as orthostatic disorders and post-urination syncope. Excessive blood pressure variability (BPV) according to aging leads to aggravation of hypertensive target organ damage due to both disturbed baroreflex function and arterial stiffening. We developed continuous BP monitoring sensor using newly developing device 'wearable BP sensor', as our advantageous approach of without a cuff-stress. The new mobile device could reflect continuous beat-to-beat systolic BP, heart rate(HR), these very close changes and double product(sBPX HR) as a major indicator of cardiac lead, in consistent with cuff-based BP value. Our new challenge using this device might approach to the potential to achieve the quality-up of treatment strategy with consideration for very short-term BPV.
More Related Videos
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
10:45A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings
Published on: January 22, 2018
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Errors occurring during blood pressure monitoring
Several factors...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)