Related Experiment Video
Updated: Mar 29, 2026

Psychophysiological Assessment of the Effectiveness of Emotion Regulation Strategies in Childhood
Published on: February 11, 2017
Validity, specificity, feasibility and acceptability of a brief pediatric distress thermometer in outpatient clinics
Lori Wiener1, Haven Battles1, Sima Zadeh1
1National Cancer Institute, Pediatric Oncology Branch, Bethesda, MD, USA.
Objective:
Psychosocial distress is under-recognized in children with cancer and other serious medical illnesses because of a focus on pressing medical concerns.
Aims:
This study assessed the validity, inter-rater reliability, sensitivity/specificity, acceptability, and feasibility of administration of a pediatric distress thermometer (DT) designed to screen for the presence of psychosocial distress in youth with serious medical illnesses.
Materials & Methods:
Two hundred eighty-one patient-caregiver-provider triads were enrolled from two hospital outpatient clinics. Patients diagnosed with cancer and other life-threatening diseases, caregivers, and providers completed the DT and a DT acceptability rating. Patients and caregivers completed standardized measures of anxiety, depression, pain, and fatigue. Providers completed a measure of disease severity. Data collectors completed a feasibility rating.
Results:
The DT was significantly correlated with both caregiver and patient reports of depression, anxiety, pain, and fatigue, exhibiting concurrent validity. Parent, child, and caregiver report demonstrated significant, moderate inter-rater reliability, with lower concordance between raters in the youngest age group. The DT is a sensitive instrument for screening of psychosocial distress when compared with the selected gold standard (Brief Symptom Inventory 18 depression subscale and the Children's Depression Inventory). The DT is not highly specific but quickly identifies those in need of further psychosocial assessment.
Discussion:
Screening, using an adapted pediatric DT, is valid, feasible, and acceptable to patients, caregivers, and medical providers across chronic medical illnesses.
Conclusion:
As patient and caregiver reports are not always concordant, both patient and caregiver report of distress are important for the provider to obtain clinically meaningful information to guide interventions. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...