Association of Ambient Air Quality with Male's Pulmonary Function in Kolkata City, India
1Office of the Secretary, Faculty Councils for Postgraduate Studies.
Background:
Kolkata is one of the polluted metropolitan cities in India where health effects of air pollution are raising serious concern.
Objectives:
Purpose of the present study was to analyze association between levels of air pollutants and pulmonary function of adult males living in two different air pollutant zones of Kolkata.
Methods:
Air pollution data of two ambient air quality monitoring stations located at Rabindrabharati and Victoria Memorial was collected from West Bengal Pollution Control Board, Kolkata for the period from January to March 2012. Study was conducted on 200 males (17-22 yrs), subdivided into two groups from living within 3 km radius of that two monitoring stations. They were investigated for their spirometric lung functions following method and technique recommended by American Thoracic Society. Results were expressed as mean ± SD and independent samples T test was conducted to compare between groups.
Results:
PM10, SO2 concentrations were significantly higher in Rabindrabharati zone, whereas no significant differences were noted in NO2 and CO concentrations though values were higher at Rabindrabharati than Victoria Memorial. FVC, FEV1, FEF25-75%, MVV were significantly lower in males of Rabindrabharati zone.
Conclusion:
Exposure to high air pollutant concentration might be associated with reduced pulmonary function in adult males.
Related Concept Videos
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
Pulmonary Tuberculosis I
Causative Organism
The primary infectious agent causing tuberculosis is Mycobacterium tuberculosis, a slow-growing, acid-fast, aerobic rod that exhibits sensitivity to heat and ultraviolet light. Instances of Mycobacterium bovis and Mycobacterium avium contributing to the development of TB infection are rare.
Mode of...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...


