Related Experiment Video
Updated: Mar 29, 2026

Author Spotlight: Integrating Ultrasound Imaging with Biochemical Markers for Thyroid Disease Diagnosis
Published on: February 9, 2024
The diagnosis value of acoustic radiation force impulse (ARFI) elastography for thyroid malignancy without highly
Bo-Ji Liu1, Feng Lu1, Hui-Xiong Xu2
1Department of Medical Ultrasound, Shanghai Tenth People's Hospital, Ultrasound Research and Education Institute, Tongji University School of Medicine Shanghai 200072, China ; Thyroid Institute, Tongji University School of Medicine Shanghai 200072, China.
Objective:
The aim of this study was to evaluate the potential diagnostic performance of acoustic radiation force impulse (ARFI) elastography in identifying malignancy in nodules that do not appear highly suspicious on conventional ultrasound (US).
Methods:
330 pathologically confirmed thyroid nodules (40 malignant and 290 benign; mean size, 22.0±11.6 mm) not suspicious of malignancy on conventional US in 330 patients (mean age 52.8±11.7 years) underwent ARFI elastography before surgery. ARFI elastography included qualitative ARFI-induced strain elastography (SE) and quantitative point shear wave elastography (p-SWE). ARFI-induced SE image was assessed by SE score, while p-SWE was denoted with shear wave velocity (SWV, m/s). The diagnostic performance of four criteria sets was evaluated: criteria set 1 (ARFI-induced SE), criteria set 2 (p-SWE), criteria set 3 (either set 1 or 2), criteria set 4 (both set 1 and 2). Receiver operating characteristic curve (ROC) analyses were performed to assess the diagnostic performance.
Results:
SE score ≥4 was more frequently found in malignant nodules (32/40) than in benign nodules (30/290, P<0.001). The mean SWV of malignant nodules (3.64±2.23 m/s) was significantly higher than that of benign nodules (2.02±0.69 m/s) (P<0.001). ARFI-induced SE (set 1) had a sensitivity of 80.0% (32/40) and a specificity of 89.7% (260/290) with a cut-off point of SE score ≥4; p-SWE (set 2) had a sensitivity of 80.0% (32/40) and a specificity of 57.9% (168/290) with a cut-off point of SWV ≥2.15 m/s. When ARFI-induced SE and p-SWE were combined, set 3 had the highest sensitivity (92.5%, 37/40) while set 4 had the highest specificity (95.2%, 276/290).
Conclusion:
ARFI elastography can be used for differential diagnosis of malignant thyroid nodules without highly suspicious features on US. The combination of ARFI-induced SE and p-SWE leads to improved sensitivity and specificity.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...

