Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Computed Tomography01:10

Computed Tomography

9.5K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
9.5K
Positron Emission Tomography01:29

Positron Emission Tomography

8.0K
Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
8.0K
Imaging Studies II: Positron Emission Tomography and Scintigraphy01:25

Imaging Studies II: Positron Emission Tomography and Scintigraphy

748
Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
748
Imaging Studies I: CT and MRI01:14

Imaging Studies I: CT and MRI

1.2K
Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
1.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Enhanced pre-therapy dosimetry for SSTR PET: A head-to-head preclinical assessment of [<sup>89</sup>Zr]Zr-DFO-TOC and [<sup>89</sup>Zr]Zr-DFO-TATE.

Nuclear medicine and biology·2026
Same author

Dosimetric and biological impact of activity extravasation of radiopharmaceuticals in PET imaging.

Medical physics·2024
Same author

Radiopharmaceutical extravasations: a twenty year mini-review.

Frontiers in nuclear medicine·2024
Same author

Insights into handling and delivery of Y-90 radioembolization therapies.

Frontiers in nuclear medicine·2024
Same author

Mucinous-appearing contamination of serous effusions by sodium carboxymethyl cellulose from suction canister lids.

Cancer cytopathology·2024
Same author

Data-driven head motion correction for PET using time-of-flight and positron emission particle tracking techniques.

PloS one·2022

Related Experiment Video

Updated: Mar 29, 2026

Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
10:21

Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function

Published on: August 8, 2019

8.9K

Whole-body dynamic imaging with continuous bed motion PET/CT.

Dustin R Osborne1, Shelley Acuff

  • 1Department of Radiology, University of Tennessee Graduate School of Medicine, Knoxville, Tennessee, USA.

Nuclear Medicine Communications
|December 3, 2015
PubMed
Summary

This article introduces a new way to perform whole-body dynamic PET scans using continuous bed motion. By moving the patient continuously through the scanner instead of stopping at specific intervals, doctors can capture dynamic data in just 15 minutes. This approach makes it easier to measure how tissues use glucose in a standard clinical setting. Initial tests show that this method provides reliable data comparable to traditional, longer scanning techniques. The researchers used mathematical models to estimate metabolic rates across the whole body. These results match established normal ranges for human tissue metabolism. This technique could make advanced metabolic imaging more accessible for routine patient care.

Keywords:
kinetic modelingmetabolic rate of glucosePatlak analysisclinical PET imaging

Frequently Asked Questions

More Related Videos

Functional Imaging of Brown Fat in Mice with 18F-FDG micro-PET/CT
10:53

Functional Imaging of Brown Fat in Mice with 18F-FDG micro-PET/CT

Published on: November 23, 2012

19.9K
Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
09:21

Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images

Published on: February 18, 2015

12.7K

Related Experiment Videos

Last Updated: Mar 29, 2026

Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
10:21

Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function

Published on: August 8, 2019

8.9K
Functional Imaging of Brown Fat in Mice with 18F-FDG micro-PET/CT
10:53

Functional Imaging of Brown Fat in Mice with 18F-FDG micro-PET/CT

Published on: November 23, 2012

19.9K
Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
09:21

Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images

Published on: February 18, 2015

12.7K

Area of Science:

  • Medical imaging diagnostics within continuous bed motion PET/CT research
  • Nuclear medicine physics and quantitative physiological modeling

Background:

No prior work had resolved the logistical barriers preventing widespread adoption of dynamic positron emission tomography in busy clinical settings. Traditional protocols often demand extended acquisition durations that exceed the capacity of standard hospital workflows. That uncertainty drove researchers to seek more efficient scanning alternatives for whole-body physiological assessment. Step and shoot imaging approaches frequently encounter technical complications that limit their practical utility for routine patient examinations. This gap motivated the development of faster, more streamlined data collection strategies for metabolic monitoring. Investigators have long sought to balance high-quality quantitative output with the constraints of modern medical practice. Prior research has shown that existing methods struggle to maintain both temporal resolution and broad anatomical coverage simultaneously. This study addresses these limitations by evaluating a novel movement-based acquisition strategy for clinical implementation.

Purpose Of The Study:

The aim of this study is to describe a novel imaging protocol that utilizes continuous bed motion to perform whole-body dynamic PET scans. This research addresses the significant challenge of conducting dynamic studies within the time constraints of a routine clinical environment. Traditional imaging techniques often require long acquisition periods that are impractical for standard patient care workflows. Furthermore, step and shoot methods frequently suffer from technical difficulties that hinder consistent data collection. The authors seek to demonstrate that a 15-minute protocol can provide sufficient information for quantitative physiological analysis. This work explores whether movement-based scanning can accurately estimate uptake rates and glucose metabolism. The motivation stems from the need to make advanced kinetic modeling more accessible in busy medical settings. This investigation evaluates the feasibility of integrating these dynamic protocols into everyday diagnostic practice.

Main Methods:

The review approach involved implementing a multipass acquisition strategy that moves the patient continuously through the scanner bore. Researchers utilized this movement-based design to replace traditional static intervals during the 15-minute scan duration. The team applied a population-based input function to facilitate kinetic modeling without requiring invasive arterial blood sampling. Investigators performed Patlak analysis on the collected data to derive quantitative physiological parameters for normal tissues. The study design focused on calculating net uptake rates and metabolic glucose consumption across the entire body. Analysts specifically examined liver regions to verify the stability of the kinetic model during the scanning process. The approach prioritized creating a protocol that remains feasible within a standard hospital environment. This methodology emphasizes efficiency while maintaining the quantitative rigor required for metabolic assessment.

Main Results:

Key findings from the literature indicate that the 15-minute whole-body protocol successfully generates reliable quantitative data for metabolic analysis. The researchers report that calculated metabolic rates of glucose fall well within normal ranges established by prior studies. The team successfully estimated net uptake rates and k3 values using their multipass acquisition strategy. Analysis of liver regions confirmed that the kinetic model remains stable throughout the continuous scanning process. The investigators observed that values for normal brain glucose metabolism align with previously published benchmarks. These results demonstrate that the movement-based technique provides sufficient data for complex kinetic modeling. The findings suggest that the protocol effectively overcomes the limitations of traditional step-based imaging methods. This initial data supports the clinical viability of performing dynamic PET scans within a short, routine timeframe.

Conclusions:

The authors propose that their movement-based acquisition strategy enables reliable quantitative analysis of whole-body metabolic processes. Their findings suggest that these protocols provide data consistent with established physiological benchmarks for glucose utilization. The researchers demonstrate that this approach maintains model stability when assessing specific organ regions like the liver. Synthesis and implications indicate that this method could facilitate advanced metabolic imaging within standard clinical timeframes. The team reports that calculated values for normal brain tissue align with previously documented metabolic rates. These results imply that continuous scanning offers a viable path toward broader adoption of dynamic PET diagnostics. The authors emphasize that their technique overcomes common difficulties associated with traditional step-based imaging procedures. This work provides a foundation for integrating complex kinetic modeling into routine diagnostic workflows.

The researchers utilize a multipass continuous bed motion technique combined with a population-based input function. This setup allows for Patlak modeling, which estimates net uptake rates and metabolic glucose consumption across normal tissues.

The investigators employ Patlak modeling to derive kinetic parameters. This mathematical framework is applied to multipass data to calculate metabolic rates of glucose and estimate k3 values, ensuring the stability of the analysis.

The authors state that modeling liver regions of interest is necessary to evaluate the stability of the kinetic model. This specific anatomical assessment helps confirm the reliability of the quantitative outputs derived from the continuous scanning protocol.

The study uses a population-based input function to replace individual arterial blood sampling. This component is essential for performing kinetic modeling in a clinical environment where invasive blood collection is often impractical.

The researchers measure the metabolic rate of glucose and net uptake rates. These values are compared against previously published literature to validate the accuracy of the new scanning method.

The authors suggest that this approach could enable reliable, quantitative multipass whole-body dynamic PET data in clinical settings. They propose that this method successfully addresses the time constraints that currently limit dynamic imaging applications.