Related Experiment Video
Updated: Mar 29, 2026

Artificial Lung Device Priming for In Situ Fiber Bundle Surface Grafting
Published on: March 28, 2025
Rebreather Unit to Prolong Underwater Survival Time
Carol M House1, Anneliese M Shaw, Daniel G Roiz de Sa
1Institute of Naval Medicine, Gosport, Hants, UK.
Introduction:
This study investigated whether the timing of activation affects the utility of an emergency underwater rebreather unit (RBU) when submerged in cold water.
Method:
On two successive occasions, 16 male UK Royal Marines were submerged in stirred water at 12.2°C for up to 78 s. The subjects were lowered (taking 18 s) into the water in a seated position and were instructed to take a large breath in, activate the unit, breath-hold for as long as possible, exhale into the unit, and breathe normally to and from the unit for the remainder of submersion. On one occasion the subjects were instructed to activate the RBU when the water reached chest height (Condition-1) and, on the other, prior to the feet entering the water (Condition-2). Measurements were made of the duration of breath-hold, rebreathing and submersion, exhaled oxygen and carbon dioxide concentrations, skin temperature, and heart rate.
Results:
In 16 of the 32 submersions, the breath-hold was released before the subject became fully submerged and in 8 submersions the subject requested early withdrawal from the water. Mean (SD) breath-hold duration was 14.0 (13.8) s and the duration of rebreathing was 45.9 (21.9) s. The duration of breath-hold once completely submerged was longer in Condition-1 (9.1 s) than Condition-2 (4.1 s).
Conclusions:
The study indicates the RBU should be activated just before the mouth becomes submerged rather than before entering the water, and that the RBU will prolong underwater stay time, thereby increasing survival prospects. House CM, Shaw AM, Roiz de Sa DG. Rebreather unit to prolong underwater stay time, thereby increasing survival prospects.
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Cardiopulmonary Resuscitation II: ACLS Airway Management
Acute Respiratory Failure-III
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: